Design And Construction Of Fire Alarm System In A Three Storied Building
...Making Research more of a fun
Putting smiles in the face of Students
Writing your project with precision
AFRICA'S LARGEST ONLINE
PROJECT ARCHIVES
Search Projects materials, seminars, assignments etc.
Get Professional help. Access 10000+ Works,
Over 300 Software Implementations.
...Get It Done In Record Time
DEPARTMENTS
agricultural education proje ... 0
accounting project topics 669
accounting projects topics & m ... 70
agricultural education project ... 13
agricultural engineering proje ... 33
applied biochemistry projects ... 6
banking and finance project to ... 196
biochemistry project topics an ... 2
biology education project topi ... 12
building technology project to ... 3
business administration projec ... 458
business education project top ... 5
business management project to ... 448
chemical engineering 22
chemical pathology projects to ... 6
chemistry project topics and m ... 17
co-operative and rural develop ... 99
co-operative economic and mana ... 99
computer science project topic ... 351
crop science project topics & ... 1
education project topics and m ... 319
education projects topics and ... 38
electrical and electronic proj ... 54
english language and literatur ... 7
estate management project topi ... 25
fashion design technology proj ... 12
fashion design technology proj ... 10
food science project topics an ... 199
geoinformatics and surveying p ... 4
home economics education proje ... 6
igbo language education projec ... 3
industrial chemistry project t ... 15
industrial chemistry projects ... 29
information technology project ... 2
insurance project topics 63
international relation project ... 26
introductory technology educat ... 1
latest mathematics education p ... 10
library and information scienc ... 2
list of chemistry science educ ... 8
list of computer science educa ... 45
list of economics education pr ... 16
list of english language educa ... 29
list of integrated science edu ... 25
marketing project topics 285
mass communication project top ... 272
mathematics projects topics an ... 1
mba projects topics and materi ... 81
mechanical engineering project ... 128
medical laboratory projects to ... 10
medical radiography and radiol ... 8
microbiology projects topics a ... 104
nursing project topics and mat ... 4
nursing projects topics and ma ... 15
nutrition and dietetics projec ... 22
office technology and manageme ... 128
peace studies and conflict res ... 19
philosophy projects topics and ... 7
physical and health education ... 5
physics options project topics 17
physis education project topic ... 2
physology project topics 3
political science project topi ... 6
printing technology projects t ... 2
projects topics and materials ... 2
purchasing and supply project ... 43
quantity surveying project top ... 1
sociology & psychology project ... 4
sociology and anthropology pro ... 17
statistics project topics and ... 52
thesis topics & materials for ... 11
thesis topics materials for fa ... 0
Select Department
Design And Construction Of Fire Alarm System In A Three Storied Building
Get the complete project material now!

User Guide before placing order for complete project topics and materials:

It is important that the researcher knows exactly what he is go to do so that I could be done effectively.Make sure you update any research work you purchased on our website. Do not copy word for word. Using our research is legal. Our aim is to provide project topics and materials for easy access to information and to reduce stress of moving from one book stop or library to another in the name of sourcing for one research textbook or research materials. We do not encourage any form of plagiarism. Our aim is to generate research project ideas for students. The contents of the project material provide will help students to generate new ideals. Every researcher must look around him in his immediate environment and beyond to improve the work. To order the below complete project materials, Make payment deposit or cash transfer into any of the following banks:

GTBANK

Account Name: Chi E-Concept Intl, Account Number: 0115939447

Other payment options

We accept cash deposit, cash transfer and Bitcoin.

Click on download to complete your order.Call or Whatsapp +23408063386834

CLICK HERE TO CHAT WITH OUR CUSTOMER SUPPORT TEAM ON WHATSAPP

TABLE OF CONTENT

CHAPTER ONE – INTRODUCTION

  1. Background of problem
  2. Structure of the problem
  3. Objective of the study
  4. Scope and limitation
  5. Importance of the study
  6. Definition of terms
  7. Design of the system
  8. Layout for the construction

 

 

CHAPTER TWO         -        CHARACTERISTICS OF THE COMPONENTS

  1. 5a fused, 3 pin pole plug
  2. Isolation and switching
  3. A.c. contactors
  4. The electric bell
  5. Fire/temperature detectors
  6. Connectors
  7. Flexible cord
  8. Display/control cabinet
  9. Incandescent lamp
  10. Lamp holder

 

CHAPTER THREE                        -           CONSTRUCTION
  1. Construction of the display and control unit
  2. Assemblage of the components
  3. Problems encountered, during the constructions

 

CHAPTER FOUR   -           OPERATIONAL DESCRIPTION
  1. Operation of the unit
  2. Monitoring/installation

 

CHAPTER FIVE     -           FAULT-FINDING AND PRECAUTION
  1. Fault-finding or trouble-shooting
  2. Safety precaution

Conclusion

References

Bill of quantity

CHAPTER ONE

  1. INTRODUCTION

1.1     BACKGROUND OF PROBLEM

          Fire detection system is safety system. They monitor rooms and buildings continuously for indication of fire outbreak and give alarm directly if one occurs.

          Both the British Factory Acts 1961 and the officers shops and railway premises Acts 1963 stiputed minimum requirements in the case of fire that there shall be clear and audible warning throughout the building. Also, an earlier statutory requirement (section 36[7] of the factories Acts 1937) states that in any factory, hospitals, market places, homes etc. Where more than 20 persons are employed that place should be effective provision for giving warning signal in case of fire outbreak and that it shall be clearly audible throughout the building.

 

STRUCTURE OF THE PROBLEM

          The alarm is given locally (visually and audibly) in order to mobilize internal auxiliary personal e.g the works fire brigade) and inform them as to the seat of the fire. A control center performs the organization of the alarm, that is, it makes available operational aids for the fire fighting measures and automatically bring the fire protection equipment into operation. Fire detection system must be tailored to the geographical and operational conditions in each individual case fore detection system, and must be installed in accordance with the relevant regulations.

 

OBJECTIVE OF THE STUDY

          In the past and present years now, there have been serious occurrences of fire outbreaks, each of which causes destruction of articles work millions of naira. In the past few months, there was fire outbreak in NITEL Exchange building at Apapa and Ikeja all in Lagos, destroyed materials estimated to be about N2.5 million.

          These ugly situation of fire outbreak always result in frustration, instabilities and disconsolations to the individuals involved and the country at large.

          It is therefore, on the recognition of this fact that we initiated the idea of constructing the fire alarm system, which is to alert the security men or fire service men in the event of any fire outbreak.

 

SCOPE AND LIMITATION

There are two main parts of fire alarm systems:

(a)     The public fire alarm system

(b)     The private fire alarm system.

          The public fire-alarm boxes are connected to the fire station by dedicated lines. These alarms boxes also perform the function of relaying calls initiated from private fire detection system to the fire station automatically. The private fire alarm detections system are used to monitor particular limited properties. They are installed in among other places, offices and business premises, industrials and commercial undertakings, theatres, cinemas department stores, schools, old people homes, hospitals and hotels. Fire detection system consist of the control centre including  its power supply (mains equipment and battery) with the principal functions of indication control activating alarms and system management, the alarm units connected through call circuits, the monitored and unmonitored lines for controlling the local alarm and information equipment, the fire protection equipment and the circuit to the fire brigade.

          Fire alarm units are in the form of automatic fire detectors or of press bottom alarm boxes. Base of these, we extended our attention on the form and nature of a fire alarm system that will give the desired result. Careful study was extended also to such areas as choice of components, portability, durability, economic choice and of course engineering efficiency. We also did our very best to ensure that the circuit wiring conformed with set standards with regard to requirements rules and regulations of electrical installation.

          The position of the sensory unit of fire alarm system found convenient on the corridors, rooms, bath rooms or any strategic position where it is likely to be any fire outbreak. However, the sensory unit of the system should be kept at some convenient distance from the kitchen, because of the thermal characteristics of some of the relay component. Although, if installed in the kitchen should be well safeguarded against the heat that normally comes from the kitchen and should be at least 1.5 meters above the floor to avoid children’s reach.

 

IMPORTANCE OF THE STUDY

          It is hoped that the fire alarm unit will find useful application in homes, offices, hospitals, restaurants, market places, service centers etc to reduce the outbreak of fire.

         DEFINITION OF TERMS

1.6.1           SWITCH

          A Mechanical switching device capable of making carrying and breaking current under normal circuit conditions, which may include specified time currents under specified abnormal circuit conditions such as those of short circuit. It is also used for economy reasons when conserving electrical power.

TYPES OF MECHANICAL SWITCH

(a)     Push-bottom switch

(b)     Slide switch and toggle switch

(c)      Micro switch

(d)     Water switch

(e)      Electromagnetic relay

(f)      Read switch

  1. FUSE

          A fuse is a device for opening a circuit by means of conductor designed to meet when on excessive current flow. The fuse comprises of all the parts that form the complete device.           There are three types of fuses.

(a)     Rewireable fuses

(b)     Catridge fuses

(c)      High breaking capacity (HRC) fuses.

  1. CONDUCTOR

          This is a device or material which offer a low resistance to the flow of current. A conductor must be:

(a)     Of low electrical resistance

(b)     Mechanically strong and flexible

(c)      Relatively cheap

 

  1. CABLE

          A cable is of long insulated single conductor solid or stranded) or of two or more such conductors, each provided with its own insulation, which are laid up together. Basic parts of cable are:

(a)     The conductor

(b)     Insulator

 

  1. A.C. CONTACTORS

          These are mechanical devices whose function in any given system is for making and breaking of circuits on receipt of electrical signals (current) from the supply. They depend for their operation on the electromagnetic principles.

          However, it can also be defined as a device for repeatedly establishing and interrupting an electric power circuit. It can be seen from the meaning of contactor that it’s principle function is to carry the current when the contacts are closed and to interrupt the circuit by opening the contacts.

Contactors may be of various types

(a)     Manually operated

(b)     Electrically operated, that operated by air cylinder. They       may be of various sizes and details of construction.

  1. SOUNDERS

          These are devices in which electrical signals are converted into sound signals, e.g. bells, boosters, sirens etc. The types and the locations should be such that alarms are clearly audible to people using the building. They must not have a similar sound to any other device on the premises.

  1. MANUAL (BREAK THE GLASS)

          They are coloured red, and are located so that no person has to travel more than 30m from any position within the premises in order to raise the alarm. They are located on exist routes and in particular on floor landings of staircases and exit to streets. They should be fixed at a height of 1.4 above the floor at easily accessible, well illuminated, conspicuous positions free from obstruction.

 

     DESIGN OF THE SYSTEM (DESIGN PROCEDURE)

          Fig 1.1 shows the complete circuit diagram for the fire ‘Alarm system’. It gives every detail of connections in the circuit. The wires have been numbered for easy connections, and the apparatus being represented by symbols.

          In the design of this circuit, much care was taken to ensure correct polarity which in effect determines the continuity of the circuit. This was also made possible by numbering each connections.

          Nevertheless, the approach to the design of this system involve trial and error methods. After the initial design was completed, the model was set up to task the behaviour of the initial system configuration and was by no means satisfactory, and was re-designed and corresponding analysis completed.

          This process of design and analysis was repeated until a satisfactory workable system was obtained. Then a prototype physical system was constructed, built and tested to see whether or not it is satisfactory.

 

    LAYOUT FOR THE CONSTRUCTION

          The layout for this construction is based on the inter-connection of the circuit components of fig. 1.1 to achieve the desired function.

          From fig 1.1, the switch unit comprises of the main switch SI, the normal close spring-stop switch, the sensor switches which are connected using flexible wires through contactors and connectors.

          The control cabinet is made of polished plywood. Wires are connected from the contactors to the connector. The connector terminals have been numbered for easy and correct connection between the control cabinet/display cabinet and the house. The control cabinet consists of three (3) contactors each controlling each floor. The siren (horn) is connected from a loop on the three contactors so that whichever contactors that is energized, the siren together with the bell of the particular floor must be on.

          Also, from fig 1.1, it is seen that the supply from the A.C mains is connected to terminals 1 and 4 of the connector wires. The wires from the A.C source is connected to the contactors and the three contactors connected in parallel.

          The cabinet contains the detectors switches which are connected in parallel for each floor. Their connections are brought out to the connectors according to their numbers.

          The bell and the bulb on the control cabinet are connected in parallel, each being connected to the connector number outside it. The detectors and test bottoms on the cabinet are connected in parallel and each connection brought out losing the flexible w



Get the complete project material now!
CUSTOMER'S REVIEW
blessing
I so much appreciate, keep the good work on.
excellent customer support
I am happy, my project was great.
ohikhueme sylvanus
Please i need theses on Leadership and good governence in nigeria: Imperative of security in nigeria, please i would glad if my message is answered immediatly. Thanks
Tony
This site have all scholars needs for their project, i can testify to that.
Rita
A site with great relief to scholars.
1 - 5 of 96 Reviews
PROJECT INFO

UID : 12766 PRICE :